Nitra Combined Heat and Power Powerplant

Nitra Combined Heat and Power Powerplant

3,12 MW of electricity and 3,2 MW of heat will be produced from natural gas in KGE Nitra with two cogeneration units MP 2000 M-BCU

 

The core of the local powerplant, which supplies heat to Chrenová district of Nitra city, are two container cogeneration units Martin Power with MTU engines (part of Rolls Royce Power Systems group). The biggest curiosity of the whole powerplant is that cogeneration units use the combination of standard pipeline natural gas with low-LHV natural gas from local source. Cogeneration units work in parallel with the mains and in case of power outage are securely stopped with help of MP 30 P genset.

Important factor during projection and realization was total surpression of negative noise or emission influences to surrounding housing and environment, and brownfield revitalisation after collapsed mazut heating plant with high accent to architectonic value.

Greenhouse, Babindol

Greenhouse, Babindol

Cogeneration units for natural gas

 

Cogeneration units MP 1500 C-CU and MP 250 N-CU use standard gas and supply greenhouse for growing tomatoes. Electric energy is used for supply of the lighting and heated water is used to heat the greenhouse.

MP 1500 C-CU with Caterpillar engine is installed in noiseproof 40 ft container with separate room for power and control cabinets. Exhaust gas heat exchanger with bypass, exhaust silencer and ventilation duct with dust filters are installed on the roof.

MP 250 N-CU with MAN engine is installed in custom made noiseproof canopy suitable for outdoor installation.

Biogas plant, Gabčíkovo

Biogas plant, Gabčíkovo

Cogeneration unit for biogas from corn silage

 

Cogeneration unit MP 1250 J-BCU with Jenbacher engine is installed in noiseproof 40 ft container. Due to time pressure reasons whole assembly of the CHP has been done directly on the installation site. Container features three separate rooms. Main room contains biogas genset with 999 kW power and components of heating circuit, gas regulation elements, lube oil system and other appliances. Power cabinets are located in separate room with own entrance for lowering noise impact of the engine to operator. Third smallest room is for inlet air treatment. Exhaust gas heat exchanger is located on the container roof. Stack with exhaust silencer, outlet heat exchanger and external dry coolers are located next to the container.

Water-treatment plant, Nitra

Water-treatment plant, Nitra

Cogeneration units for sewage gas

 

Two cogeneration units MP 400 G with Iveco engines have been installed in 2005 as a part of water-treatment plant reconstruction. When new operating company took over the operation of energetic center of the plant, it has been decided to replace one of the old CHP units with new unit MP 250 N-BCU with MAN engine.

Cogeneration unit works according to signal from upper level autonomous control system which regulates the power of CHP and parallel gas boilers according to actual gas production and power and heat consumption of the plant. TTS Martin company has been general contractor of this renovation responsible for supply of cogeneration unit as well as upper level control system.

Energyrent

Energyrent

460 kVA genset designed for rental

 

Genset MP 460 O with power 460 kVA designed for rental to customers. Genset is stationary, carried on truck during transport.

Backup of small hydroelectric powerstations

Backup of small hydroelectric powerstations

Gensets for backuping powerplants in Bešeňová and Dubnica nad Váhom

 

Two gensets MP 30 B with power 35 kVA for backuping small water powerplant. Genset in Bešeňová is open genset situated in engine room. Genset in Dubnica nad Váhom is in weatherproof canopy situated outside.

Small mobile gensets

Small mobile gensets

Two small genset for water powerplant Dubovany

 

Gensets MP 30 B and MP 40 B with power 35 kVA and 44 kVA in weatherproof canopy. Both gensets are installed on homologized chassis. Gensets are designed as power sources on places, where no electricity is available.

Hydroelectric powerplants Drahovce and Hričov

Hydroelectric powerplants Drahovce and Hričov

Backuping of main systems in powerplants

 

Two gensets MP 300 I with power 300 kVA in silenced canopies with residential silencer on the roof. Gensets are backuping main control systems during blackout.

Stredoslovenská energetika

Stredoslovenská energetika

5 pcs of mobile gensets

 

5 pcs of gensets with canopy MP 325 O mounted on chassis up to 6 tons. Each genset has power 325 kVA. Gensets are intended for backuping of mains or as prime source of electricity.

Gensets for SEPS

Gensets for SEPS

Container gensets for Slovak electricity transmission system in combination with UPS sources

 

SEPS Bratislava – Container genset MP 640 O with automatic starting for supply of the main building and data center of SEPS in combination with 3 x 250 kVA UPS in container.

SEPS Rimavská Sobota – Container genser MP 300 I for substation supply.

Compressor station Nea Messimvria, Greece

Compressor station Nea Messimvria, Greece

Backup generator of compressor station

 

Genset MP 1000 P with power of 1000 kVA in container. Air inlet and outlet are through electric louvers. Residential silencer with noise reduction -30 dB is on the roof of container. Fuel tank with volume of 5000 l with gear pump for refilling ensures continuous 24 hour operation. Container is equipped with automatic fire extinguishing system.

Thermal power plant Orapa, Botswana

Thermal power plant Orapa, Botswana

Genset in container for starting of the thermal power plant

 

Genset MP 1000 P with power 1030 kVA fitted into 30′ container. Genset is intended for suppliing power during starting procedures of thermal power plant near city Orapa in Botswana. 1800 l fuel tank with filling from outside is fitted in container. Container was certified for sea transport because of transport to the installation place. Residential silencer mounted on the roof of the container is composed of two parts and during transport was placed inside the container, next to genset and fuel tank.

Power plant Yunus Emre, Turkey

Power plant Yunus Emre, Turkey

Biggest genset produced so far

 

MP 2250 M with 2250 kVA power produced and installed in thermal powerplant Yunus Emre in Turkey. Genset is installed inside of the insulated container with external cooling system on the roof. Whole genset is designed for backup emergency cooling of the powerplant during blackout or fault.

Oil platform

Oil platform

Genset on the oil platform

 

Genset in canopy MP 50 I with power of 50 kVA. Genset is intended for backuping of the main systems on the oil platform in Caspian sea.

Oil platform in Caspian sea

Oil platform in Caspian sea

2 pcs of container gensets MP 900 P are prime energy source on the platform

 

Martin Power gensets powered by Perkíns are specially made according to norms for oil platforms and internal directives of customer. They are designed to resist rough off-shore environmental conditions and serve as primary electricity source for oil platform in Caspian sea in Turkmenistan.